XFC550 vfd for motor control, 3 phase 380V
Features
- ● 4 sets of motor control parametersThe system is equipped with four sets of motor control parameters to accommodate four motors with varying process requirements and power segments.This feature addresses the issue of VFD backup and replacement at the project site. The motor parameters can be preset for each group, allowing for seamless switching through the DI terminal during use, without the need for additional adjustments.● Flexible port configuration:Users have the flexibility to choose I/O expansion cards based on their specific digital and analog function requirements, offering convenience for design and debugging.● Rich extensions:The XFC550 series inverters support the simultaneous application of two built-in expansion cards, which can be combined to realize a variety of complex system control functions.One channel is for function and communication extensions (such as IO, PLC programmable, etc.), while the other channel is for an encoder expansion card (compatible with differential, OC interface encoder, and resolver expansion card, etc.).● High-performance stall control:The high-performance over-current and over-voltage stall control can effectively meet the varied load requirements of different mechanical characteristics, allowing the motor to adapt to both hard and soft mechanical characteristics. This makes it suitable for a wide range of engineering equipment applications.
Basic Parameters
Item
Parameter
Power supply
Rated supply voltage
3 phase 380V ~ 480V
Allowed voltage fluctuations
-15%~+10%
Rated supply frequency
50/60Hz
Allowed Frequency Fluctuations
±5%
Output
Max output voltage
Three-phase 380V~480V
Go after the input voltage
Max Output frequency
500Hz
Carrier Frequency
0.5 ~ 16kHz (automatic adjustment according to the temperature, and the adjustment range differs for different models )
Overload capacity
150% rated current 60s;
180% rated current 3s.
Basic Functions
Frequency setting resolution
Digital setting: 0.01Hz
Analog setting: max frequency * 0.025%
Control Mode
Open Loop Vector Control (SVC)
Closed Loop Vector Control (FOC)
V/f Control
Pull-in torque
0.3Hz/150% (SVC)
0 Hz/180% (FOC)
Speed range
1 : 200(SVC)
1 : 1000 (FOC)
Speed Stabilizing accuracy
±0.5%(SVC)
±0.02% (FOC)
Torque Control Precision
±5% (FOC)
Torque boost
Automatic torque boost
Manual torque increase 0.1% ~ 30.0%
V/F Curve
Three ways:
linear type;
multi-point type;
N-th power V/F curve (n=1.2, 1.4, 1.6, 1.8, 2)
Acceleration and deceleration curve
Linear or S-curve acceleration and deceleration;
4 kinds of acceleration and deceleration time.
Adjustable range 0.0~6500.0S
DC braking
Frequency of DC braking: 0.00Hz ~ max frequency
Braking time: 0.0s ~ 36.0s
Braking action current value: 0.0% ~ 100.0%
Jogging control
Jogging frequency range:0.00Hz ~ 50.00Hz
Jog acceleration- deceleration time:0.0s ~ 6500.0s
Simple PLC, multi-stage speed operation
Up to 16-stage speed operation via built-in PLC or control terminal
Built-in PID
Implementing closed-loop control in process control applications
Overvoltage and overcurrent stall control
Automatically limit current and voltage during operation to prevent fault shutdown due to frequent over-current and over-voltage
Fast current limiting function
Reduce overcurrent fault shutdown to ensure the normal operation of theVFD
Control interface
Digital input
5 multi-function digital inputs.
One of which supports max 100kHz pulse input function
Analog input
2 analog inputs.
Both supporting 0 ~ 10V or 0 ~ 20mA analog input, switch voltage or current input via jumper
Digital output
2 open-collector digital outputs.
One of which supports max 100KHz square wave output
Analog output
1 analog output.
Supporting 0 ~ 10V or 0 ~ 20mA analog output, switch voltage or current output via jumper
Relay output
1-channel relay output, including 1 normally open contact, 1 normally closed contact
Standard communication interface
1 channel RS485 communication interface
Expansion interface
Function expansion interface
Connectable to IO expansion card, PLC programmable expansion card, etc.
Operation panel
LED digital display
5-digit display of parameters and settings
Indicator light
4 status indications, 3 unit indications
Button’s Function
5 function buttons including 1 multi-function button. The function can be set via parameter P0 - 00
Shuttle Knob
Add, minus and confirm
Parameter copy
Fast upload and download parameters
Protective function
Basic protection
Input and output phase loss, overvoltage, undervoltage, overheating, overload, overcurrent, short circuit, voltage and current limiting, fast current limiting and other protection functions
Environment
Operation condition
Indoor, no conductive dust and oil, etc.
Operating ambient temperature
-10°C ~ +40°C (40°C ~ 50°C, derate 1.5% for every 1°C increase in temperature
Humidity
Less than 95% RH, no condensation
Operating altitude
No derating below 1000m, derate by 1% for every 100m elevation above 1000m
Ambient temperature for Storage
-20℃ ~ +60℃
Vibration
Less than 5.9m/s² (0.6g)
Installation method
Wall-mounted or flush-mounted installation in the cabinet
(Need to choose the appropriate installation accessories)
IP degree of protection
IP20
Model Specifications
-
Model
Motor power / kW
Rated input
Capacity / kVA
Rated input
current / A
Rated output
current / A
XFC550-3P4-1k50G-BEN-20
1.5
3.2
4.8
4
XFC550-3P4-2k20G-BEN-20
2.2
4.5
6.8
5.6
XFC550-3P4-4k00G-BEN-20
4
7.9
12
9.7
XFC550-3P4-5K50G-BEN-20
5.5
11
16
13
XFC550-3P4-7K50G-BEN-20
7.5
14
21
17
XFC550-3P4-11K0G-BEN-20
11
20
30
25
XFC550-3P4-15K0G-BEN-20
15
27
41
33
XFC550-3P4-18K5G-BEN-20
18.5
33
50
40
XFC550-3P4-22K0G-BEN-20
22
38
57
45
XFC550-3P4-30K0G-NEN-20
30
51
77
61
XFC550-3P4-37K0G-NEN-20
37
62
94
74
XFC550-3P4-45K0G-NEN-20
45
75
114
90
XFC550-3P4-55K0G-NEN-20
55
91
138
109
XFC550-3P4-75K0G-NEN-20
75
123
187
147
XFC550-3P4-90K0G-NEN-20
90
147
223
176
XFC550-3P4-110KG-NEN-20
110
179
271
211
XFC550-3P4-132KG-NEN-20
132
167
253
253
XFC550-3P4-160KG-NEN-20
160
201
306
303
XFC550-3P4-185KG-NEN-20
185
233
353
350
XFC550-3P4-200KG-NEN-20
200
250
380
378
XFC550-3P4-220KG-NEN-20
220
275
418
416
XFC550-3P4-250KG-NEN-20
250
312
474
467
XFC550-3P4-280KG-NEN-20
280
350
531
522
XFC550-3P4-315KG-NEN-20
315
393
597
588
XFC550-3P4-355KG-NEN-20
355
441
669
659
XFC550-3P4-400KG-NEN-20
400
489
743
732
XFC550-3P4-450KG-NEN-20
450
550
835
822
Note: Please contact our sales staff for model selection of 500K and above.
Dimensions
-
Model
W
H
D
w
h
h1
d
t
Fixing screws
Net Weight
XFC550-3P4-1K50G-BEN-20
110
228
177
75
219
200
172
1.5
M5
2.5kg/
5.5lb
XFC550-3P4-2K20G-BEN-20
-
Model
W
H
D
w
h
h1
d
t
Fixing screws
Net Weight
XFC550-3P4-4K00G-BEN-20
140
268
185
100
259
240
180
1.5
M5
3.2kg/7.1lb
XFC550-3P4-5K50G-BEN-20
XFC550-3P4-7K50G-BEN-20
XFC550-3P4-11K0G-BEN-20
170
318
225
125
309
290
220
5kg/11lb
XFC550-3P4-15K0G-BEN-20
XFC550-3P4-18K5G-BEN-20
190
348
245
150
339
320
240
6kg/13.2lb
XFC550-3P4-22K0G-BEN-20
-
Model
W
H
D
w
h
h1
d
t
Fixing screws
Net Weight
XFC550-3P4-30K0G-NEN-20
260
500
260
200
478
450
255
1.5
M6
17kg/37.5lb
XFC550-3P4-37K0G-NEN-20
XFC550-3P4-45K0G-NEN-20
295
570
307
200
550
520
302
2
M8
22kg/48.5lb
XFC550-3P4-55K0G-NEN-20
XFC550-3P4-75K0G-NEN-20
350
661
350
250
634
611
345
2
M10
48kg/105.8lb
XFC550-3P4-90K0G-NEN-20
XFC550-3P4-110KG-NEN-20
XFC550-3P4-132KG-NEN-20
450
850
355
300
824
800
350
2
M10
91kg/200.7lb
XFC550-3P4-160KG-NEN-20
-
Model
W
H
D
w
h
h1
h2
d
W1
Fixing screws
Net Weight
XFC550-3P4-185KG-NEN-20
340
1218
560
200
1150
1180
53
545
400
M12
210kg/463.1lb
XFC550-3P4-200KG-NEN-20
XFC550-3P4-220KG-NEN-20
XFC550-3P4-250KG-NEN-20
XFC550-3P4-280KG-NEN-20
XFC550-3P4-315KG-NEN-20
340
1445
560
200
1375
1410
56
545
400
245kg/540.2lb
XFC550-3P4-355KG-NEN-20
XFC550-3P4-400KG-NEN-20
XFC550-3P4-450KG-NEN-20
Accessories (Optional)
-
Image
Expansion type
Model No.
Function
Install port
Install quantity
IO
expansion card
XFC5-IOC-00
5 digital inputs, 1 analog input, 1 relay output, 1 open collector output, and 1 analog output can be added, with CAN interface.
X630
1
Programmable expansion card
XFC5-PLC-00
Connect with the VFD to form a PLC+VFD combination, compatible with Mitsubishi PLC programming environment.
The card has 5 digital inputs, 1 analog input, 2 relay outputs, 1 analog output, and RS485 interface.
X630
1
Profibus-DP expansion card
XFC5-PFB-00
It has Profibus-DP communication function, fully supports Profibus-DP protocol, and supports baud rate adaptive function, which allows the VFD to be connected to the Profibus communication network to realize real-time reading of all function codes of the VFD and realize field bus control.
X630
1
CANopen expansion card
XFC5-CAN-00
The VFD can be connected to the high-speed CAN communication network to realize field bus control.
The CANopen expansion card supports Heartbeat protocol, NMT messages, SDO messages, 3 TPDOs, 3 RPDOs, and emergency objects.
X630
1
Ethercat expansion card
XFC5-ECT-00
With Ethercat communication function and fully supports the Ethercat protocol, which allows the VFD to be connected to the Ethercat communication network to realize real-time reading of the VFD function code and field bus control.
X630
1